KTAD series externally heated desiccant air dryers are certificatedย by international standards such as ISO, ASME, CE, TUV and SGS. Unrivaled quality of original partsย areย maintenance-freeย and provided withย long service life and high efficiency, canย keep your compressed air equipment operating at its best.
Kotech KTAD series externally heated desiccant air dryer uses desiccants (such as activated alumina, molecular sieves) to reduce the moisture content in compressed air. The desiccant air dryer contains two working towers filled with desiccant, alternately adsorbing water molecules and regenerating air to discharge water molecules in a cycle to achieve the drying effect.
After the desiccant absorbs enough moisture, it is taken out of the dryer through the regenerated air flow, the external heat source helps enhance the drying and regeneration process while saving energy. Because of the external heat source, KTAD series desiccant air dryer can reduce the regenerated airย consumption to 4-6% through micro-heat regeneration technologyย which is the leading level over the world.
KTAD series externally heated desiccant air dryer can reduce the pressure dew point of compressed air to -40โ ~ -70โ, and the compressed air processing capacity range is 1.2-200Nm3/min(42.3-7026cfm), which is suitable for various fields and industrial occasions.
Kotech’s extended cycle time design can significantly save up to 80% of energy for KTAD series desiccant air dryer, while greatly increasing its lifespan.
KTAD series externally heated desiccant air dryers adopt a double tower design, with two drying towers for adsorption drying and regeneration drying respectively.
- Saturated compressed air passes through tower A, and the desiccant absorbs moisture. This helps to lower the dew point to discharge dry compressed air.
- Once the desiccant in container one reaches the set saturation, the air will switch to tower B to combine with the low-saturation desiccant.
- As the air passes through tower B, tower A will begin to regenerate the air and regenerate the desiccant material with the help of an external heater.
- When tower B reaches the set saturation, the air will switch through tower A to enter the next drying cycle until the designed pressure dew point is reached.
Configurations
- External heat source helps save energy
- PLC color touch screen controller
- Desiccant dryer energy management systemย matches supply to demandโUp to 80% in energy savings
- Heatless backup for more uptime
- Dewย point controlย -20ยฐC/-70ยฐC dewย point performance
- Alarm systems designed to help reduce downtime with easyย detection and diagnostics
- Remote monitoring of operation status, data trends and alarmsย via email or text alerts
- Desiccant designed for higher packing density increasesย efficiency and reliable operation
- Highย performance switching valves help provide worry-freeย performance tailored to your application
- Engineered to stand up to harsh environments
- Rugged frame with forklift pockets for easy transit and installation
- Single pre-filter and after-filter mounted
- ASME/CRN vessels
- ETL listed (UL/CSA standards)
Standard options
|
Additional options
|
Model | Capacity | Pipe connection diameter | Dimension(mm) | Weight | ||
Nm 3 /min | L | W | H | Kg | ||
KTAD-1MXF | 1.2 | ZG1 | 638 | 570 | 1310 | 120 |
KTAD-2MXF | 2.4 | ZG1 | 638 | 570 | 1690 | 140 |
KTAD-3MXF | 3.8 | ZG1 | 860 | 570 | 1456 | 220 |
KTAD-6MXF | 6.5 | ZG1.5 | 880 | 680 | 1897 | 380 |
KTAD-8MXF | 8.5 | ZG2 | 984 | 984 | 1833 | 430 |
KTAD-10MXF | 10.7 | ZG2 | 1084 | 1084 | 2009 | 520 |
KTAD-13MXF | 13.5 | ZG2 | 1084 | 1084 | 2015 | 580 |
KTAD-18MXF | 18 | ZG2.5 | 1084 | 1084 | 2100 | 640 |
KTAD-20MXF | 23 | DN80 | 1300 | 1300 | 2253 | 730 |
KTAD-25MXF | 28 | DN80 | 1300 | 1300 | 2528 | 870 |
KTAD-30MXF | 35 | DN80 | 1410 | 1410 | 2530 | 960 |
KTAD-40MXF | 45 | DN100 | 1700 | 1700 | 2620 | 1150 |
KTAD-50MXF | 55 | DN125 | 1823 | 1823 | 2684 | 1380 |
KTAD-60MXF | 65 | DN125 | 1823 | 1823 | 2747 | 1600 |
KTAD-80MXF | 85 | DN125 | 2013 | 2013 | 2800 | 2580 |
KTAD-100MXF | 100 | DN150 | 2300 | 1500 | 2933 | 3800 |
KTAD-200MXF | 200 | DN200 | 3670 | 2330 | 3660 | 6500 |
KTAD series externally heated desiccant air dryers are certificatedย by international standards such as ISO, ASME, CE, TUV and SGS. Unrivaled quality of original partsย areย maintenance-freeย and provided withย long service life and high efficiency, canย keep your compressed air equipment operating at its best.
Kotech KTAD series externally heated desiccant air dryer uses desiccants (such as activated alumina, molecular sieves) to reduce the moisture content in compressed air. The desiccant air dryer contains two working towers filled with desiccant, alternately adsorbing water molecules and regenerating air to discharge water molecules in a cycle to achieve the drying effect.
After the desiccant absorbs enough moisture, it is taken out of the dryer through the regenerated air flow, the external heat source helps enhance the drying and regeneration process while saving energy. Because of the external heat source, KTAD series desiccant air dryer can reduce the regenerated airย consumption to 4-6% through micro-heat regeneration technologyย which is the leading level over the world.
KTAD series externally heated desiccant air dryer can reduce the pressure dew point of compressed air to -40โ ~ -70โ, and the compressed air processing capacity range is 1.2-200Nm3/min(42.3-7026cfm), which is suitable for various fields and industrial occasions.
Kotech’s extended cycle time design can significantly save up to 80% of energy for KTAD series desiccant air dryer, while greatly increasing its lifespan.
KTAD series externally heated desiccant air dryers adopt a double tower design, with two drying towers for adsorption drying and regeneration drying respectively.
- Saturated compressed air passes through tower A, and the desiccant absorbs moisture. This helps to lower the dew point to discharge dry compressed air.
- Once the desiccant in container one reaches the set saturation, the air will switch to tower B to combine with the low-saturation desiccant.
- As the air passes through tower B, tower A will begin to regenerate the air and regenerate the desiccant material with the help of an external heater.
- When tower B reaches the set saturation, the air will switch through tower A to enter the next drying cycle until the designed pressure dew point is reached.
Configurations
- External heat source helps save energy
- PLC color touch screen controller
- Desiccant dryer energy management systemย matches supply to demandโUp to 80% in energy savings
- Heatless backup for more uptime
- Dewย point controlย -20ยฐC/-70ยฐC dewย point performance
- Alarm systems designed to help reduce downtime with easyย detection and diagnostics
- Remote monitoring of operation status, data trends and alarmsย via email or text alerts
- Desiccant designed for higher packing density increasesย efficiency and reliable operation
- Highย performance switching valves help provide worry-freeย performance tailored to your application
- Engineered to stand up to harsh environments
- Rugged frame with forklift pockets for easy transit and installation
- Single pre-filter and after-filter mounted
- ASME/CRN vessels
- ETL listed (UL/CSA standards)
Standard options
|
Additional options
|
Model | Capacity | Pipe connection diameter | Dimension(mm) | Weight | ||
Nm 3 /min | L | W | H | Kg | ||
KTAD-1MXF | 1.2 | ZG1 | 638 | 570 | 1310 | 120 |
KTAD-2MXF | 2.4 | ZG1 | 638 | 570 | 1690 | 140 |
KTAD-3MXF | 3.8 | ZG1 | 860 | 570 | 1456 | 220 |
KTAD-6MXF | 6.5 | ZG1.5 | 880 | 680 | 1897 | 380 |
KTAD-8MXF | 8.5 | ZG2 | 984 | 984 | 1833 | 430 |
KTAD-10MXF | 10.7 | ZG2 | 1084 | 1084 | 2009 | 520 |
KTAD-13MXF | 13.5 | ZG2 | 1084 | 1084 | 2015 | 580 |
KTAD-18MXF | 18 | ZG2.5 | 1084 | 1084 | 2100 | 640 |
KTAD-20MXF | 23 | DN80 | 1300 | 1300 | 2253 | 730 |
KTAD-25MXF | 28 | DN80 | 1300 | 1300 | 2528 | 870 |
KTAD-30MXF | 35 | DN80 | 1410 | 1410 | 2530 | 960 |
KTAD-40MXF | 45 | DN100 | 1700 | 1700 | 2620 | 1150 |
KTAD-50MXF | 55 | DN125 | 1823 | 1823 | 2684 | 1380 |
KTAD-60MXF | 65 | DN125 | 1823 | 1823 | 2747 | 1600 |
KTAD-80MXF | 85 | DN125 | 2013 | 2013 | 2800 | 2580 |
KTAD-100MXF | 100 | DN150 | 2300 | 1500 | 2933 | 3800 |